Eaton SPI9000 Instrukcja Użytkownika Strona 113

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 136
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 112
Troubleshooting Charts Using Fault Codes
9000X AF Drives MN04001004E—May 2011 www.eaton.com 103
F36—Control Unit
F37—Device Change
F38—Device Added (Indication Only)
F39—Device Removed
F36
F36?
No
Y
es
Reset the fault
Test and/or replace control board
with functioning one according to
instructions in service manual.
Replace defective parts as
recommended in spare parts lists
Clear fault memory
F37
Reset the fault
Clear fault memory
Note: F37 should appear when same
type of power unit and/or option
board have been changed
Note: Faulty board is displayed
on panel bottom line
1 = Control card A = Slot A
2 = Control unit B = Slot B
3 = Power card C = Slot C
4 = Power unit D = Slot D
5 = Adapter card E = Slot E
F38
Reset the fault
Clear fault memory
Note: F38 should appear when
same type of option board
has been added
Note: Faulty board is displayed
on panel bottom line
1 = Control card A = Slot A
2 = Control unit B = Slot B
5 = Adapter card C = Slot C
D = Slot D
E = Slot E
F39
Reset the fault
Clear fault memory
Note: F39 should appear when
an option board has
been removed
Note: Faulty board is displayed
on panel bottom line
A = Slot A
B = Slot B
C = Slot C
D = Slot D
E = Slot E
5 = Adapter card
Przeglądanie stron 112
1 2 ... 108 109 110 111 112 113 114 115 116 117 118 ... 135 136

Komentarze do niniejszej Instrukcji

Brak uwag